Welcome To Arizer Support

Select a Support Category

Arizer Extreme Q Support

All the topics and information you need for the Extreme Q.
  • 1 x Extreme Q Multi-Purpose Heater
  • 1 x Extreme Q Power Adapter
  • 1 x Extreme Q Remote Control
  • 2 x Extreme Q Glass Cyclone Bowl
  • 1 x Extreme Q Glass Aromatherapy Dish
  • 2 x Interchangeable Extreme Q Glass Whip Mouthpiece
  • 1 x Glass Stirring Tool
  • 1 x Extreme Q 3′ Whip (Silicone)
  • 1 x Extreme Q All-Glass Mini Whip
  • 2 x Extreme Q Balloon with Frosted Glass Mouthpiece
  • 1 x Extreme Q Spare Flat Screen
  • 1 x Extreme Spare Q Dome Screen
  • 1 x Sample Aromatic Botanicals
  • 1 x Extreme Q Owner’s Manual

The Control Panel consists of the LCD and four buttons – the Power button, the Menu button, and the Up & Down Arrow button. Use the Menu button to select the different settings and the Arrow buttons to adjust them.

The Extreme Q display can be set to Celsius or Fahrenheit, and has a wide temperature range of 50° C – 260° C (122° F – 500° F). The temperature is adjustable in 1-degree Celsius increments with the Control Panel buttons on the unit and with the Remote Control.

To adjust the temperature, on the control panel press the Up or Down Arrow buttons, or on the remote control press one of the preset temperature buttons or use the plus (+) or minus (-) buttons.

Note: The outside of the device does not get hot — it is high grade, dual-wall, stainless steel that stays cool to the touch. The glass parts will get hot, so they should be left to cool before handling and must be handled carefully.

The quiet and powerful three-speed fan can be operated with the Control Panel buttons on the unit and with the Remote Control.

If it is taking longer than 2-3 minutes to fill the bag / balloon it might be time for you to clean or replace some parts such as the Dome Screen and the Balloon. If you check these things and a problem persists, please refer to the Troubleshooting section below.

A full range of parts and accessories to equip your Extreme Q are available for purchase here.

If you can’t find the part you need send us an email to: service@arizer.com with a description of the part you need.

Note: In case of accidental damage the internal glass part (the Glass Heater Cover) comes with step-by-step repair instructions and is available for purchase on the Extreme Q Accessories page.

Small, sturdy, and lightweight. Sized to fit conveniently on any counter, desk, or table.

  • Weight (no parts):442 grams
  • Height (no parts):170 mm
  • Base Diameter:165 mm

Equipped for worldwide use with an input capacity of 110-240V with international safety certifications.

ROHS

The Extreme Q carries a lifetime warranty on the heating element and a limited 3-Year warranty covering defects in materials or workmanship. Glass is not covered under warranty. Retain proof of purchase for warranty service. Returning the product and costs incurred are the responsibility of the user. Arizer will repair or replace warrantied items at our discretion. The warranty does not cover units damaged by dropping, tampering, unauthorized service performed or attempted, modifying the unit, misuse or abuse.

Cautions, Disclaimers and Warnings (Read Before Use)

First Time Use – Examine box contents to ensure all included parts are in good condition, not damaged from shipping.  Check glass parts for cracks or breakage.  Packaging materials, bags, & small parts may pose a choking hazard.  Keep out of reach/use from children, minors, and pets.  To burn off any residues from packaging, turn on the unit, set the temperature to 220° C, and let the unit heat for 5 – 10 minutes.

Warning – Hot Parts – Handle hot parts and glass parts with care.  Allow heating unit and hot parts to cool before handling, storing, or placing on any surface where damage from hot parts can occur.  

Parts are made from strong scientific quality borosilicate glass, but all borosilicate glass is breakable so handle with care and caution.  Avoid tapping on hard surfaces to prevent cracking and breaking.  If glass is dropped or sustains an impact, examine for cracking, chipping and weakness before use. Do not expose hot glass parts to cold water or extreme temperature change as this may result in cracking/breaking.

Product contains electrical and delicate parts — do not drop.  If damaged do not operate.  To protect/prevent against electric shock/fire never immerse or operate the product in or around any water/liquids.  Do not stick or pour anything in the unit or place near flammable material.  Do not store/operate/expose the unit and contents to extreme temperatures.  Do not open the unit – doing so may cause electric shock and unauthorized service may void the warranty.

Do not yank or twist the cord to unplug.  To disconnect, turn the unit off and remove/unplug the cord by gripping the plug body and pulling it from the outlet.

Do not let the cord hang over the edge of tables/counters or touch hot surfaces.  The unit should be situated safely so the cord cannot be pulled on or tripped over. If an extension cord is needed make sure to use a grounded three prong power cord (grounding-type 3-wire cord).  

Do not leave the unit turned on and left unattended.

The information contained in this manual is an aid in understanding the various theories and practices, preparation and uses, and does not represent an endorsement or guarantee the efficiency or use of its preparation.  This information is not intended in any way to replace or supersede professional consultations.

The information contained herein is for instructional and cautionary purposes only.  In no way is the information contained herein intended to be a medical or prescriptive guide or to be used for diagnosing or treating a health problem, condition, or disease.  It is the user’s responsibility to consult a Physician or Medical Professional.  This product is not licensed as a medical device, use unit only for its intended use.

Safety Certifications

Equipped for worldwide use with an input capacity of 110-240V and international safety certifications.

ROHS

Limitation of Liability (Read before use)

Failure to read or follow instructions, improper or careless use may lead to personal injury.  Arizer and affiliated companies will not assume any liability for injury or damage resulting from the use or misuse of this device.  Due to the fragility and nature of glass Arizer and affiliated companies are not responsible for cuts or injuries sustained from breakage.  Arizer and affiliated companies are not liable for injuries or burns associated from touching hot parts. Arizer and affiliated companies are not liable for failures to comply with these warnings and safety guidelines. If you do not agree with these conditions return the product immediately before use.

This product is intended for use with the botanicals described herein — Arizer and affiliated companies are not liable for use with other than those botanicals described herein.  Company’s liabilities for damages in connection with the product and its parts shall not exceed the purchase price of the product.

IMPORTANT – Obey local laws.  Not all essential oils, botanicals and herbs are legal for use in every Country or State.  Check your Local, State, Federal and Importation laws before ordering botanicals.  This device is meant for legal use only.

The Balloon consists of the Bag, Balloon Connector, Balloon Cap and Frosted Glass Balloon Mouthpiece.

1. Slip the silicone balloon cap over the glass mouthpiece so it rests between the glass bulbs.

2. Insert the bottom (unfrosted end) of the glass mouthpiece through the top of the hole of the silicone balloon connector. Push until the bulbs of the mouthpiece is fully on each side of the cap.

3. Gather the open end of the balloon and insert it through the large opening in the threaded base until there is enough material to fold evenly back past the base threads.

 

Note: The size of the bag can be adjusted by changing how much material is pulled through the opening. Ensure excess material is trimmed.

 

4. Push the two pieces of the balloon connector together until they lock. Slide the connector up the glass until it rests against the bulb closest to the frosted mouthpiece.

Arizer xq2 balloon assembly

If you experience an issue with your Extreme Q send an email to service@arizer.com and an expert Arizer customer service representative will reply as soon as possible to troubleshoot and determine the best way to resolve any issues. To help expedite your service request please include a description of the problem, your full name, your shipping address, the serial number on the bottom of your device, and a copy of your sales receipt.

628078800034

Shipping Disclaimer:

Please note that our processing and shipping times are not guaranteed at this time. Rest assured we’re working hard to meet and exceed your expectations. Thank you in advance for your patience and support!

Contact Arizer Support

Fill out the form below or email us and we will be happy to assist you!

Toll Free

Leave us a voice message and we'll get back to you ASAP
888-291-0521

Wholesale

Interested in becoming a Retailer or Distributor?
Click Here